What is the iodine-131 blood-volume question from JEE Advanced 2017?
The JEE Advanced 2017 iodine-131 blood-volume answer is approximately 5 litres: decay determines the remaining total activity, while uniform mixing determines the sample’s share. This Physics, Atoms and Nuclei question is from JEE Advanced 2017 Paper 1. It requires a single-digit integer response, not a multiple-choice selection.
Iodine-131 undergoes beta decay to an isotope of xenon with a half-life of 8 days. A small amount of serum labelled with iodine-131 is injected into a person’s blood. Its initial activity is:
The serum spreads uniformly throughout the bloodstream in less than half an hour. A 2.5 ml blood sample collected 11.5 hours after injection has an activity of 115 Bq. Find the approximate total blood volume in litres, using:
The question bank tags this problem medium, with an expected solving time of 120 seconds. These are metadata, not a universal speed benchmark.
How do you calculate the activity remaining after 11.5 hours?
Start the decay clock at injection and use the full 11.5 hours. Mixing makes the later sample representative of the whole bloodstream; it does not delay radioactive decay. Do not subtract the mixing interval, because decay continues while the serum mixes. Calculate the remaining total activity before finding the sample’s share.
Define the initial activity and elapsed time, then convert the half-life to hours:
The decay constant and remaining total activity are:
Leave the exponential unevaluated until the sampling equation is ready. Its exponent must be dimensionless:
Bq means decays per second, but that does not force the exponent to use seconds. Using hours consistently makes the exponential a unitless multiplier; the activity remains in Bq.
How does a 2.5 ml sample reveal the total blood volume?
Uniform mixing means equal activity per ml everywhere in the blood at the sampling time. The sample and the whole bloodstream therefore have the same activity concentration, not the same activity. The sample carries the same fraction of the total activity as it does of the total blood volume.
Define the total blood volume and sample quantities:
Equal activity concentrations give:
Substitute the decay expression:
Using numerical volumes in ml:
Rearrange before evaluating:
The units check: sample volume multiplied by total activity, divided by sample activity, leaves a volume. The official model accounts for radioactive decay only. Do not introduce a biological clearance correction that the problem does not supply.
How does the calculation give the integer answer 5?
The decay factor is approximately 0.9581, giving a blood volume of approximately 5 litres. The exponent is small enough for the supplied first-order approximation. Keep the negative sign: activity decreases with elapsed time, so the decay factor must be less than one.
Calculate the exponent:
The supplied approximation uses the negative argument:
This gives:
Insert the decay factor into the volume expression:
Following the official worked solution’s approximate reporting:
The physical result is approximately 5 litres. Enter only the single-digit integer:
For a direction check, ignoring decay gives:
Including decay must reduce the inferred volume: less total activity remains to produce the measured concentration. Both results round to the same integer, but that coincidence does not make a decay-free calculation valid.
What goes wrong if you treat 8 days as 8 hours?
The inferred volume falls to about 1.91 litres, producing the wrong integer entry 2. This integer-response question has no supplied wrong options; this is a wrong numerical route, not an answer choice.
The inconsistent substitution is:
It effectively treats the half-life as 8 hours. For diagnosing this error only:
The mistake invents roughly half a day of rapid decay under an 8-hour half-life. The actual 8-day half-life permits only a small loss over the sampling interval.
Do not use the small-exponent approximation here: an exponent near one is not small. Convert the half-life and elapsed time to the same unit before calculating the exponent.
How do you solve two related tracer questions?
Change only the named quantity: sample volume in the first variation, elapsed time in the second. Both are original practice variations on the verified JEE Advanced 2017 Atoms and Nuclei PYQ, not additional questions from the 2017 paper. Keep the uniform-mixing and decay-only assumptions.
Question 1: At the same 11.5-hour sampling time, what activity would a 5.0 ml sample have?
Only the sampled volume changes; the activity concentration at that instant is unchanged. Doubling the volume doubles its activity:
Question 2: With unchanged blood volume, what would a fresh 2.5 ml sample’s activity be 8 days after the original sample?
Only the sampling time changes. One additional half-life halves the activity concentration, so the same sample volume has half the original activity:
For your next tracer problem, write the elapsed time from the stated starting event first. Then equate sample and whole-blood activity concentrations at the same instant.
Next step: the past-paper archive on JEEnius and search every JEE Main paper from 2002 and every Advanced paper from 2007, by year, subject or chapter, each with a worked solution (free).
Read next: How to Study Permutations and Combinations JEE: A Study Plan.
Frequently asked questions
What is the answer to the JEE Advanced 2017 iodine-131 blood-volume question?
The total blood volume is approximately 5 litres. The question requires a single-digit integer response, so enter 5.
Should I subtract the mixing time from 11.5 hours?
No. Radioactive decay begins at injection and continues during mixing, so use the full 11.5 hours. Uniform mixing makes the later blood sample representative of the bloodstream; it does not delay decay.
How do you calculate blood volume from the sample activity?
Uniform mixing gives equal activity concentrations in the sample and the whole bloodstream at the sampling time. Therefore, total blood volume equals sample volume multiplied by the remaining total activity, divided by sample activity. Use the decay-corrected total activity, not the initial injected activity.
Can I use hours in the decay formula if activity is in Bq?
Yes, provided the decay constant and elapsed time use matching units. Convert the 8-day half-life to 192 hours, then use a decay constant of 0.7/192 per hour with 11.5 hours. The exponent is dimensionless, so the activity remains in Bq.